Liquid Analysis Online Analysis Ammonia Ammonia Sensitive Sensor Monitoring ammonia leakage in refrigerating plants Applicable for a medium temperature of at least -8 °C Special PTFE membrane Easy replacement of membrane Enquire Now Ammonia Transmitter/Controller Plain language operation, multilingual Graphic display with backlight Easy to install plug-type terminal strips Electrode monitoring Enquire Now Ammonia Accessories Installation of probes 120 x 12 mm possible For 1 and 3 probes with Pg13.5 connection Favorable chemical compatibility Perfect probe protection Various process connections Enquire Now Oxygen (dissolved) Oxygen Measuring Cells Use of indicating device/controller AQUIS 500 RS according to data sheet 202569 Low operating costs due to reduced maintenance requirements (no electrolyte changes and no polarization voltage) Greater calibration intervals due to lower drift behavior High measuring accuracy even for low concentrations Short response time No minimum inflow (no oxygen consumption) Secure, digital measured value transmission Enquire Now Oxygen Transmitter/Controller Plain language operation, multilingual Graphic display with background lighting Calibration routine for dissolved oxygen, chlorine, total chlorine Surface-mounted case protection type IP 67 Enquire Now Oxygen Accessories Measurement of dissolved oxygen (DO) in aqueous solutions Safe 1-point calibration 2-wire transmitter (for basic and standard version) Electrical isolation of measurement signal (DO) and output signal (mA) Easy connection to an existing system (e.g PLC) Can be used as stand-alone system in maximum version Compensation of temperature, atmospheric pressure and salinity Further processing of the temperature of the medium is possible (separate Pt 1000 or 2-wire transmitter) Enquire Now TSS/Silt/Sludge blanket Total Suspended Solids Optical sensor based on absorptiometry Range of measure SS : 0-50 g/L Sludge blanket 0-100 % Turbidity 0-4000 FAU Digital communication Modbus RS-485 Strong sensor Enquire Now Silt Measuring Instrument Two probe types, 1.6 and 5.0 mm (ID) tubing Easy to clean probe parts Exchangeable transmitter and receiver Electronics insulated from medium Immersible version available Enquire Now Sludge blanket Optical sensor based on absorptiometry SS : 0-50 g/L Sludge blanket 0-100 % Turbidity 0-4000 FAU Digital communication Modbus RS-485 Strong sensor Enquire Now Portables Micro 800 Conductivity/TDS Conductivity 0 – 200,000 µS/cm, 0 – 200 mS/cm Total Dissolved Solids (TDS) 0 – 200,000 mg/L, 0 – 200 ppt Salinity 0 – 50.00 ppt Temperature -10 ⁰C to 110 ⁰C Micro 800 Multiparameter pH -2.00 to 16.00 Oxidation Reduction Potential (ORP) -2000 to +2000 mV Conductivity 0 – 200,000 µS/cm, 0 – 200 mS/cm Total Dissolved Solids (TDS) 0 – 200,000 mg/L, 0 – 200 ppt Temperature -10 ⁰C to 110 ⁰C Micro 800 pH Dissolved Oxygen 0.00 – 20.00 mg/L, 0 – 200% saturation Temperature 0.0 – 100 ⁰C Enquire Now