Liquid Analysis

Online Analysis

Ammonia

Ammonia Sensitive Sensor

  • Monitoring ammonia leakage in refrigerating plants
  • Applicable for a medium temperature of at least -8 °C
  • Special PTFE membrane
  • Easy replacement of membrane

Ammonia Transmitter/Controller

  • Plain language operation, multilingual
  • Graphic display with backlight
  • Easy to install plug-type terminal strips
  • Electrode monitoring

Ammonia Accessories

  • Installation of probes 120 x 12 mm possible
  • For 1 and 3 probes with Pg13.5 connection
  • Favorable chemical compatibility
  • Perfect probe protection
  • Various process connections

Oxygen (dissolved)

Oxygen Measuring Cells

  • Use of indicating device/controller AQUIS 500 RS according to data sheet 202569
  • Low operating costs due to reduced maintenance requirements (no electrolyte changes and no polarization voltage)
  • Greater calibration intervals due to lower drift behavior
  • High measuring accuracy even for low concentrations
  • Short response time
  • No minimum inflow (no oxygen consumption)
  • Secure, digital measured value transmission

Oxygen Transmitter/Controller

  • Plain language operation, multilingual
  • Graphic display with background lighting
  • Calibration routine for dissolved oxygen, chlorine, total chlorine
  • Surface-mounted case protection type IP 67

Oxygen Accessories

  • Measurement of dissolved oxygen (DO) in aqueous solutions
  • Safe 1-point calibration
  • 2-wire transmitter (for basic and standard version)
  • Electrical isolation of measurement signal (DO) and output signal (mA)
  • Easy connection to an existing system (e.g PLC)
  • Can be used as stand-alone system in maximum version
  • Compensation of temperature, atmospheric pressure and salinity
  • Further processing of the temperature of the medium is possible (separate Pt 1000 or 2-wire transmitter)

TSS/Silt/Sludge blanket

Total Suspended Solids

  • Optical sensor based on absorptiometry
  • Range of measure
  • SS : 0-50 g/L
  • Sludge blanket 0-100 %
  • Turbidity 0-4000 FAU
  • Digital communication Modbus RS-485
  • Strong sensor

Silt Measuring Instrument

  • Two probe types, 1.6 and 5.0 mm (ID) tubing
  • Easy to clean probe parts
  • Exchangeable transmitter and receiver
  • Electronics insulated from medium
  • Immersible version available

Sludge blanket

  • Optical sensor based on absorptiometry
  • SS : 0-50 g/L
  • Sludge blanket 0-100 %
  • Turbidity 0-4000 FAU
  • Digital communication Modbus RS-485
  • Strong sensor

Portables

Micro 800 Conductivity/TDS

  • Conductivity 0 – 200,000 µS/cm, 0 – 200 mS/cm
  • Total Dissolved Solids (TDS) 0 – 200,000 mg/L, 0 – 200 ppt
  • Salinity 0 – 50.00 ppt
  • Temperature -10 ⁰C to 110 ⁰C

Micro 800 Multiparameter

  • pH -2.00 to 16.00
  • Oxidation Reduction Potential (ORP) -2000 to +2000 mV
  • Conductivity 0 – 200,000 µS/cm, 0 – 200 mS/cm
  • Total Dissolved Solids (TDS) 0 – 200,000 mg/L, 0 – 200 ppt
  • Temperature -10 ⁰C to 110 ⁰C

Micro 800 pH

  • Dissolved Oxygen 0.00 – 20.00 mg/L, 0 – 200% saturation
  • Temperature 0.0 – 100 ⁰C